ANKA lithium battery-powered smoke alarms are cost-effective and simple to set up and install.
In Queensland, homeowners may self-install compliant photoelectric smoke alarms powered by a non-removable 10-year battery. However, 240V hardwired smoke alarms must be installed by a licensed electrician.
Your alarms—and any remote control supplied with your order—are paired and tested by InterconnectedQLD before shipping. You do not need to pair them yourself.
Simply turn on each alarm, remove the plastic battery isolation tab from the remote control, if supplied, and test the complete system before installation.
The pairing instructions below are provided as a reference guide only. You may need them if you:
Do not reset or re-pair your alarms unless necessary, as doing so will remove the pairing completed before shipping.
The alarms will sound for approximately 10 seconds and then silence automatically.
Once you have confirmed that every alarm activates, the system is ready to install.
The following steps are not required when you first receive your order. Your system has already been paired and tested by InterconnectedQLD.
Use these instructions only when adding another device, replacing a device or troubleshooting a pairing problem.
The master alarm remains in pairing mode for approximately one minute.
If you cannot pair every alarm within that time, repeat Step 2 to place the master alarm back into pairing mode, then continue pairing the remaining alarms.
Alarms already paired to the network will remain paired and do not need to be paired again.
If an alarm does not activate during the system test:
Where practicable, smoke alarms must be installed on the ceiling.
A smoke alarm must not be installed:
For a sloping ceiling, the alarm must be installed between 500 mm and 1,500 mm from the apex.
If mounting an alarm on the ceiling is not practicable, different requirements apply to installation on a wall or exposed beam.
Always follow the alarm manufacturer’s mounting instructions. Special placement requirements apply to stairways, sloping ceilings, exposed beams and other non-standard ceiling arrangements.
These placement requirements are set out in the Building Regulation 2021. If you are unsure about the correct location for an alarm, seek advice from a suitably qualified professional before installation.